Deteksi Pembuluh Darah pada Citra Fundus Retina Menggunakan Gabungan Metode Segementasi Pembuluh Darah Lebar dan Tipis
Abstract
Organs in the human body provide a lot of knowledge about human body health. One of them is the organ in the human eye, more specifically the retina.Furthermoreeven some accute diseases can be detected through the retina image. One of the diseases that can be detected through retinal images is diabetic retinopathy. This disease can be identified through segmentation to find abnormalities in the retinal blood vessels. These abnormalities include enlarged blood vessels, abnormal branching, and so on. Manual detection of blood vessels on the retina is less accurate, so a comperhensive program is required in order to segment the blood vessels in eye fundus images, more accurately. In this research, some method and algorithms are approached by combining the segmentation process for wide vessels and the segmentation process for thin vessels. There are three stages in this research. First, the Contrast Limited Adaptive Histogram Equalization (CLAHE) algorithm and 2D Gabor Wavelet are applied as the preprocessing stage. Then, active contour and region growing methods are required as the processing to segment the thin and wide vessels in fundus retina image. And the last stage is postprocessing using the logical operator method or. The trial in this research uses color eye fundus images on the DRIVE dataset consisting of 20 retinal photos. By using this dataset, the average accuracy is 94.32%, sensitivity is 77.09% and specificity is 96.04% in 20 trials.
The Authors submitting a manuscript do so on the understanding that if accepted for publication, copyright of the article shall be assigned to Jurnal Teknologi Informasi dan Terapan (J-TIT) and Department of Information Technology, Politeknik Negeri Jember as publisher of the journal. Copyright encompasses rights to reproduce and deliver the article in all form and media, including reprints, photographs, microfilms, and any other similar reproductions, as well as translations. Authors should sign a copyright transfer agreement when they have approved the final proofs sent by Jurnal Teknologi Informasi dan Terapan (J-TIT) prior to the publication. The copyright transfer agreement can be download here .
Jurnal Teknologi Informasi dan Terapan (J-TIT) and Department of Information Technology, Politeknik Negeri Jember and the Editors make every effort to ensure that no wrong or misleading data, opinions or statements be published in the journal. In any way, the contents of the articles and advertisements published in Jurnal Teknologi Informasi dan Terapan (J-TIT) are the sole responsibility of their respective authors and advertisers.
Users of this website will be licensed to use materials from this website following the Creative Commons Attribution 4.0 International License. No fees charged. Please use the materials accordingly.
This work is licensed under a Creative Commons Attribution-Share A like 4.0 International License
You are free to:
- Share — copy and redistribute the material in any medium or format
- Adapt — remix, transform, and build upon the material for any purpose, even commercially.
- The licensor cannot revoke these freedoms as long as you follow the license terms.